NOx Optical Bench for Vehicle Emission Appication
Introduction
The bench adopts multi-component photodetector, anti-interference algorithm to measure concentratio of SO2, NO and NOx. It is in high accuracy and realiability, with fast response time and wide range of applications. Both USB interface and RS232 are available for data output.
UV-DOAS technology
Compared with other detection methods (electrochemistry and NDIR), the adopted technology can realize simultaneous and direct measurement of NO and NO2 with advantages of fast response time, high accuracy, small volume, simple structure and no interference of background gas (like moisture). It supports MODBUS protocol and customization.
Feature
Based on UV gas analysis technology with years of research experience; self-developed core technology and algorithm; strong market competitiveness
Fast response speed, solve NO2 absorption problem, T90≤ 3.5s (NO2 index),T95≤ 4.5s
Without interference of substances like H2O, dust, HC and CO2
Specification
Range: NO 0-4000ppm, NO2 0-1000 ppm
Relative linearity error:≤ ±4%/≤±25ppm
Repeatability: ≤2%
Stability:≤2%
Zero drift:≤ ±2%F.S/24h
Span drift:≤ ±2%F.S/24h
Response time:T90≤3.5s, T10≤3.5s
Anti-interference requirement:NO NO2≤±1%
Gas flow:2±0.1L/min
Supply voltage:220VAC,55W
Interface:RS232, adopt Modbus protocol
Measure NO and NO2 simultaneously and directly, solve the problem that conversion efficiency of conventional converter will gradually decrease over time