Continuous Emission Monitoring System (CEMS)

WaterVolatileOrganic

Application

Application for exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant, cement, glass, lime factory, ceramics factory, sinter, coke oven, deSOx, deNOx technology

Gas sample in flue passes through the probeHeat pipe, filter, sampling solenoid valve, sampling pump and filter in the chassis, then reaches to measuring cell. After analysis the concentration of all components, the sample gas will be drained through sampling pump.

By controlling sampling ball valve and purging solenoid valve, the system can regularly purge to the probe. It can also realize the regular calibration of the analyzer.

The system has the function of whole calibration.

 

Measuring technique

SO2, NO, NO2UV DOAS 

O2electrochemical (built-in), zirconiaextraposition

COelectrochemical or infrared NDIR technology   

CO2infrared NDIR technology 

Measurement range

SO2NOx0-300-3000ppm0-100-300ppm0-20-100ppm;(optional, can be customized,O2(0-25%), Humidity0-40%, Dust: (0-200mg/m3)(0-10g/m3)

Flow rate: 0-40m/scan be customized

Humidity0-800℃(can be customized

Pressure-10kPa10kPacan be customized

Output signal

RS2325×4-20mA, configurable

Input signal

3× DC4-20mA, configurable

Power supply

220VAC, 2500W

Operating conditions

Ambient temperature: -20~50 Ambient humidity: 5%95%RH, non-condensing

Heating temperature

120ºC180ºC 

Flow rate

1.5±0.1L/min

External dimension

600mm×800mm×1800mm

Weight

≈200kg

Enclosure rating

IP65

Features

1. Fast dehydration and cooling by two-step condensing, reducing contact time of air and water, lower SO2 loss

2. Analyzer uses micro-heating technology, reducing maintenance cycle of lens

3. Fast sampling by loop sampling pumps, shorten response time

4. Dehydration and dedust by multi-stage filtration, high reliability

5. Calibration for whole precess  can be realized