Portable FTIR Gas Analyzer

13

> Application

 

 

Apply to dust and noise online monitoring in construction sites, roads, residential, factory sector, tourism, waste incineration plants and other construction sites and production situations.

 

> Specification

Principle

fourier transform infrared spectroscopy(FTIR) 

Range

SO2: 0~75mg/m3, NO: 0~200mg/m3

NO2: 0~40mg/m3, NOx: 0~200mg/m3

CH4: 0~20mg/m3, NH3: 0~10mg/m3 

HCl: 0~15mg/m3, HF: 0~10mg/m3

CO: 0~75mg/m3, CO2:(0~20)%

Zero  Drift

2%F.S./7d

Span Drift

2%F.S./7d

Repeatability

≤2%

Sampling Flow

(1.5±0.5)L/min

Response Time:

≤90s

Enclosure Protection

IP41

Humidity

 0 ~ 95% RH

Temperature

0~45℃

Digital Comm.

RS485/USB

Working Temperature

-20℃~ + 50℃

 

> Feature

 

 

1. Warming up is no required for the analyzer to realize fast measurement.

2. Applicable for high humidity and dust occasion

3. Optical length up to 13m; extremely low detection limit; high range dynamics; satisfy the monitoring of small emission limit 

4. By applying OLS and PLS techniques and selecting, interference from H2O or others can be effectively eliminated

5. Quick site sampling, analysis and easy operation